| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170 |
- /*
- * FreeModbus Libary: A portable Modbus implementation for Modbus ASCII/RTU.
- * Copyright (c) 2006 Christian Walter <wolti@sil.at>
- * All rights reserved.
- *
- * Redistribution and use in source and binary forms, with or without
- * modification, are permitted provided that the following conditions
- * are met:
- * 1. Redistributions of source code must retain the above copyright
- * notice, this list of conditions and the following disclaimer.
- * 2. Redistributions in binary form must reproduce the above copyright
- * notice, this list of conditions and the following disclaimer in the
- * documentation and/or other materials provided with the distribution.
- * 3. The name of the author may not be used to endorse or promote products
- * derived from this software without specific prior written permission.
- *
- * THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
- * IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
- * OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
- * IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
- * INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
- * NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
- * DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
- * THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
- * (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
- * THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
- *
- * File: $Id: mbconfig.h,v 1.15 2010/06/06 13:54:40 wolti Exp $
- * $Id: mbconfig.h,v 1.60 2013/08/13 21:19:55 Armink Add Master Functions $
- */
- #ifndef _MB_CONFIG_H
- #define _MB_CONFIG_H
- #include "sdkconfig.h" // for KConfig options
- #ifdef __cplusplus
- PR_BEGIN_EXTERN_C
- #endif
- /* ----------------------- Defines ------------------------------------------*/
- /*! \defgroup modbus_cfg Modbus Configuration
- *
- * Most modules in the protocol stack are completly optional and can be
- * excluded. This is specially important if target resources are very small
- * and program memory space should be saved.<br>
- *
- * All of these settings are available in the file <code>mbconfig.h</code>
- */
- /*! \addtogroup modbus_cfg
- * @{
- */
- /*! \brief If Modbus Master ASCII support is enabled. */
- #define MB_MASTER_ASCII_ENABLED ( CONFIG_FMB_COMM_MODE_ASCII_EN )
- /*! \brief If Modbus Master RTU support is enabled. */
- #define MB_MASTER_RTU_ENABLED ( CONFIG_FMB_COMM_MODE_RTU_EN )
- /*! \brief If Modbus Master TCP support is enabled. */
- #define MB_MASTER_TCP_ENABLED ( CONFIG_FMB_COMM_MODE_TCP_EN )
- /*! \brief If Modbus Slave ASCII support is enabled. */
- #define MB_SLAVE_ASCII_ENABLED ( CONFIG_FMB_COMM_MODE_ASCII_EN )
- /*! \brief If Modbus Slave RTU support is enabled. */
- #define MB_SLAVE_RTU_ENABLED ( CONFIG_FMB_COMM_MODE_RTU_EN )
- /*! \brief If Modbus Slave TCP support is enabled. */
- #define MB_TCP_ENABLED ( CONFIG_FMB_COMM_MODE_TCP_EN )
- #if !CONFIG_FMB_COMM_MODE_ASCII_EN && !CONFIG_FMB_COMM_MODE_RTU_EN && !MB_MASTER_TCP_ENABLED && !MB_TCP_ENABLED
- #error "None of Modbus communication mode is enabled. Please enable one of (ASCII, RTU, TCP) mode in Kconfig."
- #endif
- /*! \brief This option defines the number of data bits per ASCII character.
- *
- * A parity bit is added before the stop bit which keeps the actual byte size at 10 bits.
- */
- #ifdef CONFIG_FMB_SERIAL_ASCII_BITS_PER_SYMB
- #define MB_ASCII_BITS_PER_SYMB ( CONFIG_FMB_SERIAL_ASCII_BITS_PER_SYMB )
- #endif
- /*! \brief The character timeout value for Modbus ASCII.
- *
- * The character timeout value is not fixed for Modbus ASCII and is therefore
- * a configuration option. It should be set to the maximum expected delay
- * time of the network.
- */
- #ifdef CONFIG_FMB_SERIAL_ASCII_TIMEOUT_RESPOND_MS
- #define MB_ASCII_TIMEOUT_MS ( CONFIG_FMB_SERIAL_ASCII_TIMEOUT_RESPOND_MS )
- #endif
- /*! \brief Timeout to wait in ASCII prior to enabling transmitter.
- *
- * If defined the function calls vMBPortSerialDelay with the argument
- * MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS to allow for a delay before
- * the serial transmitter is enabled. This is required because some
- * targets are so fast that there is no time between receiving and
- * transmitting the frame. If the master is to slow with enabling its
- * receiver then he will not receive the response correctly.
- */
- #ifndef MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS
- #define MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS ( 0 )
- #endif
- /*! \brief Maximum number of Modbus functions codes the protocol stack
- * should support.
- *
- * The maximum number of supported Modbus functions must be greater than
- * the sum of all enabled functions in this file and custom function
- * handlers. If set to small adding more functions will fail.
- */
- #define MB_FUNC_HANDLERS_MAX ( 16 )
- /*! \brief Number of bytes which should be allocated for the <em>Report Slave ID
- * </em>command.
- *
- * This number limits the maximum size of the additional segment in the
- * report slave id function. See eMBSetSlaveID( ) for more information on
- * how to set this value. It is only used if MB_FUNC_OTHER_REP_SLAVEID_ENABLED
- * is set to <code>1</code>.
- */
- #define MB_FUNC_OTHER_REP_SLAVEID_BUF ( 32 )
- /*! \brief If the <em>Report Slave ID</em> function should be enabled. */
- #define MB_FUNC_OTHER_REP_SLAVEID_ENABLED ( CONFIG_FMB_CONTROLLER_SLAVE_ID_SUPPORT )
- /*! \brief If the <em>Read Input Registers</em> function should be enabled. */
- #define MB_FUNC_READ_INPUT_ENABLED ( 1 )
- /*! \brief If the <em>Read Holding Registers</em> function should be enabled. */
- #define MB_FUNC_READ_HOLDING_ENABLED ( 1 )
- /*! \brief If the <em>Write Single Register</em> function should be enabled. */
- #define MB_FUNC_WRITE_HOLDING_ENABLED ( 1 )
- /*! \brief If the <em>Write Multiple registers</em> function should be enabled. */
- #define MB_FUNC_WRITE_MULTIPLE_HOLDING_ENABLED ( 1 )
- /*! \brief If the <em>Read Coils</em> function should be enabled. */
- #define MB_FUNC_READ_COILS_ENABLED ( 1 )
- /*! \brief If the <em>Write Coils</em> function should be enabled. */
- #define MB_FUNC_WRITE_COIL_ENABLED ( 1 )
- /*! \brief If the <em>Write Multiple Coils</em> function should be enabled. */
- #define MB_FUNC_WRITE_MULTIPLE_COILS_ENABLED ( 1 )
- /*! \brief If the <em>Read Discrete Inputs</em> function should be enabled. */
- #define MB_FUNC_READ_DISCRETE_INPUTS_ENABLED ( 1 )
- /*! \brief If the <em>Read/Write Multiple Registers</em> function should be enabled. */
- #define MB_FUNC_READWRITE_HOLDING_ENABLED ( 1 )
- /*! \brief Check the option to place timer handler into IRAM */
- #define MB_PORT_TIMER_ISR_IN_IRAM ( CONFIG_FMB_TIMER_ISR_IN_IRAM )
- /*! @} */
- #ifdef __cplusplus
- PR_END_EXTERN_C
- #endif
- #if MB_MASTER_RTU_ENABLED || MB_MASTER_ASCII_ENABLED || MB_MASTER_TCP_ENABLED
- /*! \brief If master send a broadcast frame, the master will wait time of convert to delay,
- * then master can send other frame */
- #define MB_MASTER_DELAY_MS_CONVERT ( CONFIG_FMB_MASTER_DELAY_MS_CONVERT )
- /*! \brief If master send a frame which is not broadcast,the master will wait sometime for slave.
- * And if slave is not respond in this time,the master will process this timeout error.
- * Then master can send other frame */
- #define MB_MASTER_TIMEOUT_MS_RESPOND ( CONFIG_FMB_MASTER_TIMEOUT_MS_RESPOND )
- /*! \brief The total slaves in Modbus Master system.
- * \note : The slave ID must be continuous from 1.*/
- #define MB_MASTER_TOTAL_SLAVE_NUM ( 247 )
- #endif
- #endif
|