| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303 |
- import logging
- import os
- import re
- from threading import Thread
- import ttfw_idf
- from tiny_test_fw import DUT
- LOG_LEVEL = logging.DEBUG
- LOGGER_NAME = 'modbus_test'
- # Allowed options for the test
- TEST_READ_MAX_ERR_COUNT = 3 # Maximum allowed read errors during initialization
- TEST_THREAD_JOIN_TIMEOUT = 60 # Test theread join timeout in seconds
- TEST_EXPECT_STR_TIMEOUT = 30 # Test expect timeout in seconds
- TEST_MASTER_TCP = 'mb_tcp_master'
- TEST_SLAVE_TCP = 'mb_tcp_slave'
- STACK_DEFAULT = 0
- STACK_IPV4 = 1
- STACK_IPV6 = 2
- STACK_INIT = 3
- STACK_CONNECT = 4
- STACK_START = 5
- STACK_PAR_OK = 6
- STACK_PAR_FAIL = 7
- STACK_DESTROY = 8
- pattern_dict_slave = {STACK_IPV4: (r'.*I \([0-9]+\) example_connect: - IPv4 address: ([0-9]{1,3}\.[0-9]{1,3}\.[0-9]{1,3}\.[0-9]{1,3}).*'),
- STACK_IPV6: (r'.*I \([0-9]+\) example_connect: - IPv6 address: (([A-Fa-f0-9]{1,4}::?){1,7}[A-Fa-f0-9]{1,4}).*'),
- STACK_INIT: (r'.*I \(([0-9]+)\) MB_TCP_SLAVE_PORT: (Protocol stack initialized).'),
- STACK_CONNECT: (r'.*I\s\(([0-9]+)\) MB_TCP_SLAVE_PORT: Socket \(#[0-9]+\), accept client connection from address: '
- r'([0-9]{1,3}\.[0-9]{1,3}\.[0-9]{1,3}\.[0-9]{1,3}).*'),
- STACK_START: (r'.*I\s\(([0-9]+)\) SLAVE_TEST: (Start modbus test).*'),
- STACK_PAR_OK: (r'.*I\s\(([0-9]+)\) SLAVE_TEST: ([A-Z]+ [A-Z]+) \([a-zA-Z0-9_]+ us\),\s'
- r'ADDR:([0-9]+), TYPE:[0-9]+, INST_ADDR:0x[a-zA-Z0-9]+, SIZE:[0-9]+'),
- STACK_PAR_FAIL: (r'.*E \(([0-9]+)\) SLAVE_TEST: Response time exceeds configured [0-9]+ [ms], ignore packet.*'),
- STACK_DESTROY: (r'.*I\s\(([0-9]+)\) SLAVE_TEST: (Modbus controller destroyed).')}
- pattern_dict_master = {STACK_IPV4: (r'.*I \([0-9]+\) example_connect: - IPv4 address: ([0-9]{1,3}\.[0-9]{1,3}\.[0-9]{1,3}\.[0-9]{1,3}).*'),
- STACK_IPV6: (r'.*I \([0-9]+\) example_connect: - IPv6 address: (([A-Fa-f0-9]{1,4}::?){1,7}[A-Fa-f0-9]{1,4}).*'),
- STACK_INIT: (r'.*I \(([0-9]+)\) MASTER_TEST: (Modbus master stack initialized).*'),
- STACK_CONNECT: (r'.*.*I\s\(([0-9]+)\) MB_TCP_MASTER_PORT: (Connected [0-9]+ slaves), start polling.*'),
- STACK_START: (r'.*I \(([0-9]+)\) MASTER_TEST: (Start modbus test).*'),
- STACK_PAR_OK: (r'.*I\s\(([0-9]+)\) MASTER_TEST: Characteristic #[0-9]+ ([a-zA-Z0-9_]+)'
- r'\s\([a-zA-Z\%\/]+\) value = [a-zA-Z0-9\.]+ \(0x[a-zA-Z0-9]+\) read successful.*'),
- STACK_PAR_FAIL: (r'.*E \(([0-9]+)\) MASTER_TEST: Characteristic #[0-9]+\s\(([a-zA-Z0-9_]+)\)\s'
- r'read fail, err = [0-9]+ \([_A-Z]+\).*'),
- STACK_DESTROY: (r'.*I\s\(([0-9]+)\) MASTER_TEST: (Destroy master).*')}
- logger = logging.getLogger(LOGGER_NAME)
- class DutTestThread(Thread):
- """ Test thread class
- """
- def __init__(self, dut=None, name=None, ip_addr=None, expect=None):
- """ Initialize the thread parameters
- """
- self.tname = name
- self.dut = dut
- self.expected = expect
- self.data = None
- self.ip_addr = ip_addr
- self.test_finish = False
- self.param_fail_count = 0
- self.param_ok_count = 0
- self.test_stage = STACK_DEFAULT
- super(DutTestThread, self).__init__()
- def __enter__(self):
- logger.debug('Restart %s.' % self.tname)
- # Reset DUT first
- self.dut.reset()
- # Capture output from the DUT
- self.dut.start_capture_raw_data(capture_id=self.dut.name)
- return self
- def __exit__(self, exc_type, exc_value, traceback):
- """ The exit method of context manager
- """
- if exc_type is not None or exc_value is not None:
- logger.info('Thread %s rised an exception type: %s, value: %s' % (self.tname, str(exc_type), str(exc_value)))
- def run(self):
- """ The function implements thread functionality
- """
- # Initialize slave IP for master board
- if (self.ip_addr is not None):
- self.set_ip(0)
- # Check expected strings in the listing
- self.test_start(TEST_EXPECT_STR_TIMEOUT)
- # Check DUT exceptions
- dut_exceptions = self.dut.get_exceptions()
- if 'Guru Meditation Error:' in dut_exceptions:
- raise Exception('%s generated an exception: %s\n' % (str(self.dut), dut_exceptions))
- # Mark thread has run to completion without any exceptions
- self.data = self.dut.stop_capture_raw_data(capture_id=self.dut.name)
- def set_ip(self, index=0):
- """ The method to send slave IP to master application
- """
- message = r'.*Waiting IP([0-9]{1,2}) from stdin.*'
- # Read all data from previous restart to get prompt correctly
- self.dut.read()
- result = self.dut.expect(re.compile(message), TEST_EXPECT_STR_TIMEOUT)
- if int(result[0]) != index:
- raise Exception('Incorrect index of IP=%d for %s\n' % (int(result[0]), str(self.dut)))
- message = 'IP%s=%s' % (result[0], self.ip_addr)
- self.dut.write(message, '\r\n', False)
- logger.debug('Sent message for %s: %s' % (self.tname, message))
- message = r'.*IP\([0-9]+\) = \[([0-9a-zA-Z\.\:]+)\] set from stdin.*'
- result = self.dut.expect(re.compile(message), TEST_EXPECT_STR_TIMEOUT)
- logger.debug('Thread %s initialized with slave IP (%s).' % (self.tname, result[0]))
- def test_start(self, timeout_value):
- """ The method to initialize and handle test stages
- """
- def handle_get_ip4(data):
- """ Handle get_ip v4
- """
- logger.debug('%s[STACK_IPV4]: %s' % (self.tname, str(data)))
- self.test_stage = STACK_IPV4
- def handle_get_ip6(data):
- """ Handle get_ip v6
- """
- logger.debug('%s[STACK_IPV6]: %s' % (self.tname, str(data)))
- self.test_stage = STACK_IPV6
- def handle_init(data):
- """ Handle init
- """
- logger.debug('%s[STACK_INIT]: %s' % (self.tname, str(data)))
- self.test_stage = STACK_INIT
- def handle_connect(data):
- """ Handle connect
- """
- logger.debug('%s[STACK_CONNECT]: %s' % (self.tname, str(data)))
- self.test_stage = STACK_CONNECT
- def handle_test_start(data):
- """ Handle connect
- """
- logger.debug('%s[STACK_START]: %s' % (self.tname, str(data)))
- self.test_stage = STACK_START
- def handle_par_ok(data):
- """ Handle parameter ok
- """
- logger.debug('%s[READ_PAR_OK]: %s' % (self.tname, str(data)))
- if self.test_stage >= STACK_START:
- self.param_ok_count += 1
- self.test_stage = STACK_PAR_OK
- def handle_par_fail(data):
- """ Handle parameter fail
- """
- logger.debug('%s[READ_PAR_FAIL]: %s' % (self.tname, str(data)))
- self.param_fail_count += 1
- self.test_stage = STACK_PAR_FAIL
- def handle_destroy(data):
- """ Handle destroy
- """
- logger.debug('%s[DESTROY]: %s' % (self.tname, str(data)))
- self.test_stage = STACK_DESTROY
- self.test_finish = True
- while not self.test_finish:
- try:
- self.dut.expect_any((re.compile(self.expected[STACK_IPV4]), handle_get_ip4),
- (re.compile(self.expected[STACK_IPV6]), handle_get_ip6),
- (re.compile(self.expected[STACK_INIT]), handle_init),
- (re.compile(self.expected[STACK_CONNECT]), handle_connect),
- (re.compile(self.expected[STACK_START]), handle_test_start),
- (re.compile(self.expected[STACK_PAR_OK]), handle_par_ok),
- (re.compile(self.expected[STACK_PAR_FAIL]), handle_par_fail),
- (re.compile(self.expected[STACK_DESTROY]), handle_destroy),
- timeout=timeout_value)
- except DUT.ExpectTimeout:
- logger.debug('%s, expect timeout on stage #%d (%s seconds)' % (self.tname, self.test_stage, timeout_value))
- self.test_finish = True
- def test_check_mode(dut=None, mode_str=None, value=None):
- """ Check communication mode for dut
- """
- global logger
- try:
- opt = dut.app.get_sdkconfig()[mode_str]
- logger.debug('%s {%s} = %s.\n' % (str(dut), mode_str, opt))
- return value == opt
- except Exception:
- logger.error('ENV_TEST_FAILURE: %s: Cannot find option %s in sdkconfig.' % (str(dut), mode_str))
- return False
- @ttfw_idf.idf_example_test(env_tag='Example_Modbus_TCP')
- def test_modbus_communication(env, comm_mode):
- global logger
- rel_project_path = os.path.join('examples', 'protocols', 'modbus', 'tcp')
- # Get device under test. Both duts must be able to be connected to WiFi router
- dut_master = env.get_dut('modbus_tcp_master', os.path.join(rel_project_path, TEST_MASTER_TCP))
- dut_slave = env.get_dut('modbus_tcp_slave', os.path.join(rel_project_path, TEST_SLAVE_TCP))
- log_file = os.path.join(env.log_path, 'modbus_tcp_test.log')
- print('Logging file name: %s' % log_file)
- try:
- # create file handler which logs even debug messages
- logger.setLevel(logging.DEBUG)
- fh = logging.FileHandler(log_file)
- fh.setLevel(logging.DEBUG)
- # set format of output for both handlers
- formatter = logging.Formatter('%(levelname)s:%(message)s')
- fh.setFormatter(formatter)
- logger.addHandler(fh)
- # create console handler
- ch = logging.StreamHandler()
- ch.setLevel(logging.INFO)
- # set format of output for both handlers
- formatter = logging.Formatter('%(levelname)s:%(message)s')
- ch.setFormatter(formatter)
- logger.addHandler(ch)
- # Check Kconfig configuration options for each built example
- if (test_check_mode(dut_master, 'CONFIG_FMB_COMM_MODE_TCP_EN', 'y') and
- test_check_mode(dut_slave, 'CONFIG_FMB_COMM_MODE_TCP_EN', 'y')):
- slave_name = TEST_SLAVE_TCP
- master_name = TEST_MASTER_TCP
- else:
- logger.error('ENV_TEST_FAILURE: IP resolver mode do not match in the master and slave implementation.\n')
- raise Exception('ENV_TEST_FAILURE: IP resolver mode do not match in the master and slave implementation.\n')
- address = None
- if test_check_mode(dut_master, 'CONFIG_MB_SLAVE_IP_FROM_STDIN', 'y'):
- logger.info('ENV_TEST_INFO: Set slave IP address through STDIN.\n')
- # Flash app onto DUT (Todo: Debug case when the slave flashed before master then expect does not work correctly for no reason
- dut_slave.start_app()
- dut_master.start_app()
- if test_check_mode(dut_master, 'CONFIG_EXAMPLE_CONNECT_IPV6', 'y'):
- address = dut_slave.expect(re.compile(pattern_dict_slave[STACK_IPV6]), TEST_EXPECT_STR_TIMEOUT)
- else:
- address = dut_slave.expect(re.compile(pattern_dict_slave[STACK_IPV4]), TEST_EXPECT_STR_TIMEOUT)
- if address is not None:
- print('Found IP slave address: %s' % address[0])
- else:
- raise Exception('ENV_TEST_FAILURE: Slave IP address is not found in the output. Check network settings.\n')
- else:
- raise Exception('ENV_TEST_FAILURE: Slave IP resolver is not configured correctly.\n')
- # Create thread for each dut
- with DutTestThread(dut=dut_master, name=master_name, ip_addr=address[0], expect=pattern_dict_master) as dut_master_thread:
- with DutTestThread(dut=dut_slave, name=slave_name, ip_addr=None, expect=pattern_dict_slave) as dut_slave_thread:
- # Start each thread
- dut_slave_thread.start()
- dut_master_thread.start()
- # Wait for threads to complete
- dut_slave_thread.join(timeout=TEST_THREAD_JOIN_TIMEOUT)
- dut_master_thread.join(timeout=TEST_THREAD_JOIN_TIMEOUT)
- if dut_slave_thread.isAlive():
- logger.error('ENV_TEST_FAILURE: The thread %s is not completed successfully after %d seconds.\n' %
- (dut_slave_thread.tname, TEST_THREAD_JOIN_TIMEOUT))
- raise Exception('ENV_TEST_FAILURE: The thread %s is not completed successfully after %d seconds.\n' %
- (dut_slave_thread.tname, TEST_THREAD_JOIN_TIMEOUT))
- if dut_master_thread.isAlive():
- logger.error('TEST_FAILURE: The thread %s is not completed successfully after %d seconds.\n' %
- (dut_master_thread.tname, TEST_THREAD_JOIN_TIMEOUT))
- raise Exception('TEST_FAILURE: The thread %s is not completed successfully after %d seconds.\n' %
- (dut_master_thread.tname, TEST_THREAD_JOIN_TIMEOUT))
- logger.info('TEST_INFO: %s error count = %d, %s error count = %d.\n' %
- (dut_master_thread.tname, dut_master_thread.param_fail_count,
- dut_slave_thread.tname, dut_slave_thread.param_fail_count))
- logger.info('TEST_INFO: %s ok count = %d, %s ok count = %d.\n' %
- (dut_master_thread.tname, dut_master_thread.param_ok_count,
- dut_slave_thread.tname, dut_slave_thread.param_ok_count))
- if ((dut_master_thread.param_fail_count > TEST_READ_MAX_ERR_COUNT) or
- (dut_slave_thread.param_fail_count > TEST_READ_MAX_ERR_COUNT) or
- (dut_slave_thread.param_ok_count == 0) or
- (dut_master_thread.param_ok_count == 0)):
- raise Exception('TEST_FAILURE: %s parameter read error(ok) count = %d(%d), %s parameter read error(ok) count = %d(%d).\n' %
- (dut_master_thread.tname, dut_master_thread.param_fail_count, dut_master_thread.param_ok_count,
- dut_slave_thread.tname, dut_slave_thread.param_fail_count, dut_slave_thread.param_ok_count))
- logger.info('TEST_SUCCESS: The Modbus parameter test is completed successfully.\n')
- finally:
- dut_master.close()
- dut_slave.close()
- logging.shutdown()
- if __name__ == '__main__':
- test_modbus_communication()
|