123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143
  1. /*
  2. * FreeModbus Libary: A portable Modbus implementation for Modbus ASCII/RTU.
  3. * Copyright (c) 2006-2018 Christian Walter <cwalter@embedded-solutions.at>
  4. * All rights reserved.
  5. *
  6. * Redistribution and use in source and binary forms, with or without
  7. * modification, are permitted provided that the following conditions
  8. * are met:
  9. * 1. Redistributions of source code must retain the above copyright
  10. * notice, this list of conditions and the following disclaimer.
  11. * 2. Redistributions in binary form must reproduce the above copyright
  12. * notice, this list of conditions and the following disclaimer in the
  13. * documentation and/or other materials provided with the distribution.
  14. * 3. The name of the author may not be used to endorse or promote products
  15. * derived from this software without specific prior written permission.
  16. *
  17. * THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
  18. * IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
  19. * OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
  20. * IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
  21. * INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
  22. * NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
  23. * DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
  24. * THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
  25. * (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
  26. * THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
  27. *
  28. * File: $Id: mbconfig.h,v 1.14 2006/12/07 22:10:34 wolti Exp $
  29. * $Id: mbconfig.h,v 1.60 2013/08/13 21:19:55 Armink Add Master Functions $
  30. */
  31. #ifndef _MB_CONFIG_H
  32. #define _MB_CONFIG_H
  33. #ifdef __cplusplus
  34. PR_BEGIN_EXTERN_C
  35. #endif
  36. /* ----------------------- Defines ------------------------------------------*/
  37. /*! \defgroup modbus_cfg Modbus Configuration
  38. *
  39. * Most modules in the protocol stack are completly optional and can be
  40. * excluded. This is specially important if target resources are very small
  41. * and program memory space should be saved.<br>
  42. *
  43. * All of these settings are available in the file <code>mbconfig.h</code>
  44. */
  45. #include <rtconfig.h>
  46. /*! \addtogroup modbus_cfg
  47. * @{
  48. */
  49. /*! \brief If Modbus Master ASCII support is enabled. */
  50. #define MB_MASTER_ASCII_ENABLED ( 0 )
  51. /*! \brief If Modbus Master RTU support is enabled. */
  52. #define MB_MASTER_RTU_ENABLED ( 1 )
  53. /*! \brief If Modbus Master TCP support is enabled. */
  54. #define MB_MASTER_TCP_ENABLED ( 0 )
  55. /*! \brief If Modbus Slave ASCII support is enabled. */
  56. #ifdef PKG_MODBUS_SLAVE_ASCII
  57. #define MB_SLAVE_ASCII_ENABLED ( 1 )
  58. #else
  59. #define MB_SLAVE_ASCII_ENABLED ( 0 )
  60. #endif
  61. /*! \brief If Modbus Slave RTU support is enabled. */
  62. #ifdef PKG_MODBUS_SLAVE_RTU
  63. #define MB_SLAVE_RTU_ENABLED ( 1 )
  64. #else
  65. #define MB_SLAVE_RTU_ENABLED ( 0 )
  66. #endif
  67. /*! \brief If Modbus Slave TCP support is enabled. */
  68. #ifdef PKG_MODBUS_SLAVE_TCP
  69. #define MB_SLAVE_TCP_ENABLED ( 1 )
  70. #else
  71. #define MB_SLAVE_TCP_ENABLED ( 0 )
  72. #endif
  73. /*! \brief The character timeout value for Modbus ASCII.
  74. *
  75. * The character timeout value is not fixed for Modbus ASCII and is therefore
  76. * a configuration option. It should be set to the maximum expected delay
  77. * time of the network.
  78. */
  79. #define MB_ASCII_TIMEOUT_SEC ( 1 )
  80. /*! \brief Maximum number of Modbus functions codes the protocol stack
  81. * should support.
  82. *
  83. * The maximum number of supported Modbus functions must be greater than
  84. * the sum of all enabled functions in this file and custom function
  85. * handlers. If set to small adding more functions will fail.
  86. */
  87. #define MB_FUNC_HANDLERS_MAX ( 16 )
  88. /*! \brief Number of bytes which should be allocated for the <em>Report Slave ID
  89. * </em>command.
  90. *
  91. * This number limits the maximum size of the additional segment in the
  92. * report slave id function. See eMBSetSlaveID( ) for more information on
  93. * how to set this value. It is only used if MB_FUNC_OTHER_REP_SLAVEID_ENABLED
  94. * is set to <code>1</code>.
  95. */
  96. #define MB_FUNC_OTHER_REP_SLAVEID_BUF ( 32 )
  97. /*! \brief If the <em>Report Slave ID</em> function should be enabled. */
  98. #define MB_FUNC_OTHER_REP_SLAVEID_ENABLED ( 1 )
  99. /*! \brief If the <em>Read Input Registers</em> function should be enabled. */
  100. #define MB_FUNC_READ_INPUT_ENABLED ( 1 )
  101. /*! \brief If the <em>Read Holding Registers</em> function should be enabled. */
  102. #define MB_FUNC_READ_HOLDING_ENABLED ( 1 )
  103. /*! \brief If the <em>Write Single Register</em> function should be enabled. */
  104. #define MB_FUNC_WRITE_HOLDING_ENABLED ( 1 )
  105. /*! \brief If the <em>Write Multiple registers</em> function should be enabled. */
  106. #define MB_FUNC_WRITE_MULTIPLE_HOLDING_ENABLED ( 1 )
  107. /*! \brief If the <em>Read Coils</em> function should be enabled. */
  108. #define MB_FUNC_READ_COILS_ENABLED ( 1 )
  109. /*! \brief If the <em>Write Coils</em> function should be enabled. */
  110. #define MB_FUNC_WRITE_COIL_ENABLED ( 1 )
  111. /*! \brief If the <em>Write Multiple Coils</em> function should be enabled. */
  112. #define MB_FUNC_WRITE_MULTIPLE_COILS_ENABLED ( 1 )
  113. /*! \brief If the <em>Read Discrete Inputs</em> function should be enabled. */
  114. #define MB_FUNC_READ_DISCRETE_INPUTS_ENABLED ( 1 )
  115. /*! \brief If the <em>Read/Write Multiple Registers</em> function should be enabled. */
  116. #define MB_FUNC_READWRITE_HOLDING_ENABLED ( 1 )
  117. /*! @} */
  118. #ifdef __cplusplus
  119. PR_END_EXTERN_C
  120. #endif
  121. #if MB_MASTER_RTU_ENABLED > 0 || MB_MASTER_ASCII_ENABLED > 0
  122. /*! \brief If master send a broadcast frame,the master will wait time of convert to delay,
  123. * then master can send other frame */
  124. #define MB_MASTER_DELAY_MS_CONVERT (200 )
  125. /*! \brief If master send a frame which is not broadcast,the master will wait sometime for slave.
  126. * And if slave is not respond in this time,the master will process this timeout error.
  127. * Then master can send other frame */
  128. #define MB_MASTER_TIMEOUT_MS_RESPOND (100 )
  129. /*! \brief The total slaves in Modbus Master system. Default 16.
  130. * \note : The slave ID must be continuous from 1.*/
  131. #define MB_MASTER_TOTAL_SLAVE_NUM ( 16 )